S4 · 高一五人小組 Grade 10 Team
設備與風管 Equipment and Ductwork
用同一份負荷資料比較兩種送風估算,整理設備能力和風管尺寸的檢查條件。 Compare two airflow estimates from the same load and document equipment and duct checks.
我的必修 Required Study
五人共學 Shared Study-
先分清峰值負荷、設備冷量、送風量與新風量。 Distinguish peak load, equipment capacity, supply airflow and outdoor air.
-
讀懂總冷量和顯熱能力,記下型錄工況。 Read total and sensible ratings and record duty conditions.
-
看懂風量、風速、風管尺寸與每米壓降。 Interpret airflow, velocity, duct size and friction per metre.
第一次練習 First Practice Task
呼出計算器 Open Calculator先載入 CFM 與直圓管的兩個獨立示例。把各方法的結果、單位、假設和一個待查問題整理成短表。 Load the separate CFM and round duct examples. Make a short table of results, units, assumptions and one open question.
- CFM 兩種算法比較 Airflow Estimate Comparison
- RTU 容量與餘量 RTU Capacity and Margin
- 等摩擦法直圓管查表 Equal-Friction Round Duct Sizing
- 完成時自查 Completion Check
- 能說明兩種 CFM 為何不同,並指出風管表適用的管形及摩擦率。 Explain why the CFM estimates differ and identify the duct geometry and friction rate used.
隊友交接 Team Handoff
向誰收資料 Inputs from Teammates
- S2
- 已標註單位、版本和假設的負荷底稿。 Load worksheet with units, revision and assumptions.
- S3、S5
- 空間與風路草圖,以及舒適、濕度和噪音方面的待查條件。 Layout and air paths, plus open comfort, humidity and noise conditions.
交出甚麼 What to Hand Off
- 給 S3、S1
- 有風管編號的風量和尺寸核對表,附候選設備的待查條件。 Duct-ID airflow and sizing checks, with equipment conditions still to verify.
- 給 S5
- 兩種風量的差異與可能影響舒適度的假設。 Differences between airflow estimates and assumptions that could affect comfort.
隨手計算器 Calculator Panel
計算結果 Results
單位一致性檢查 Unit Check
公式、單位與假設 Formulas, Units and Assumptions
Rᵢ = dᵢ ÷ kᵢ Rᵢ = dᵢ ÷ kᵢ
R總 = R內表面 + Σ Rᵢ + R外表面 Rtotal = Rinside film + Σ Rᵢ + Routside film
U = 1 ÷ R總 U = 1 ÷ Rtotal
厚度可用 mm、m 或 in,先統一成 m。k 用 W/(m·K),各項 R 用 m²·K/W。 Convert mm, m or in to metres. Use W/(m·K) for k and m²·K/W for resistance.
- 一維穩態傳熱。各層覆蓋同一面積,熱量依序穿過各層。 One-dimensional steady heat transfer. All layers cover the same area.
- 表面熱阻由學生填寫。並聯熱橋、空氣滲漏與日射另作查核。 Enter surface film resistances. Check parallel bridges, air leakage and solar gain separately.
計算結果 Results
單位一致性檢查 Unit Check
公式、單位與假設 Formulas, Units and Assumptions
Q = U × A × ΔT Q = U × A × ΔT
ΔT = T室外 − T室內 ΔT = Toutdoor − Tindoor
ΔT(K) = ΔT(°F) × 5 ÷ 9 ΔT(K) = ΔT(°F) × 5 ÷ 9
各欄按選定單位換成 W/(m²·K)、m² 和 K。華氏溫差不用減 32。 Convert U, area and ΔT into W/(m²·K), m² and K. Do not subtract 32 from a Fahrenheit difference.
- 穩態傳導。U 為整個構造的總傳熱係數,A 用扣除另計開口後的淨面積。 Steady conduction. Use net wall area after subtracting separately counted openings.
- 正值代表熱量流入房間,負值代表熱量流出。這一步只計傳導。 Positive values enter the room, negative values leave it.
單位一致性檢查 Unit Check
公式、單位與假設 Formulas, Units and Assumptions
1 BTU/h ≈ 0.293071 W 1 BTU/h ≈ 0.293071 W
1 TR = 12,000 BTU/h 1 TR = 12,000 BTU/h
目標值 = 原數值 × 來源 BTU/h 係數 ÷ 目標 BTU/h 係數 Target = original × source BTU/h factor ÷ target BTU/h factor
BTU/h、W 及 ton of refrigeration (TR) 都是傳熱率(heat transfer rate)的單位。 BTU/h, W and TR are heat transfer rates.
- 使用 International Table BTU,最後才依有效數字取位。 Uses the International Table BTU. Round at the end.
計算結果 Results
單位一致性檢查 Unit Check
公式、單位與假設 Formulas, Units and Assumptions
Q噸 = Qpeak(BTU/h) ÷ 12,000 QTR = Qpeak(BTU/h) ÷ 12,000
CFM A = 0.045 × Qpeak(BTU/h) CFM A = 0.045 × Qpeak(BTU/h)
CFM B = 400 × Q噸 CFM B = 400 × QTR
A 的係數是 CFM/(BTU/h),B 的係數是 CFM/ton。把 Qpeak 換成對應單位再乘。 Method A uses CFM per BTU/h. Method B uses CFM per refrigeration ton.
- 兩個風量係數是本課指定的比較假設。A 按負荷比率估算,B 按名義冷量比率估算。 The two airflow ratios are teaching assumptions.
- 這裡將同一筆峰值負荷換成冷凍噸作比較。實際送風、新風與設備額定風量應各自核對。 Both start from the same peak load. Check actual supply, outdoor airflow and rating separately.
計算結果 Results
單位一致性檢查 Unit Check
公式、單位與假設 Formulas, Units and Assumptions
基礎容量(ton) = Qpeak(BTU/h) ÷ 12,000 Base (TR) = Qpeak(BTU/h) ÷ 12,000
額外餘量(ton) = 基礎容量 × 餘量百分比 ÷ 100 Added (TR) = base × margin percent ÷ 100
目標容量(ton) = 基礎容量 × (1 + 餘量百分比 ÷ 100) Target (TR) = base × (1 + margin percent ÷ 100)
Qpeak 先轉成 BTU/h,再除以 12,000 BTU/h/ton。10% 對應乘數 1.10。 Convert peak load to BTU/h before dividing by 12,000 BTU/h per ton. A 10% margin is a multiplier of 1.10.
- 5%–15% 為本課試算範圍。此工具提供名義冷量,設備核對另需顯熱、除濕、風量與實際工況資料。 The margin range is a classroom assumption. Check sensible capacity, moisture removal, airflow and duty conditions separately.
計算結果 Results
單位一致性檢查 Unit Check
公式、單位與假設 Formulas, Units and Assumptions
γ = ln(RH ÷ 100) + 17.62 × T ÷ (243.12 + T) γ = ln(RH ÷ 100) + 17.62 × T ÷ (243.12 + T)
T露點 = 243.12 × γ ÷ (17.62 − γ) Tdew = 243.12 × γ ÷ (17.62 − γ)
冷凝餘量 = T玻璃表面 − T露點 Dew-point margin = Tglass − Tdew
空氣和玻璃溫度分別換成 °C。華氏讀值要先減 32,再乘 5/9。RH 用百分數輸入。 Convert absolute temperatures to °C. Enter RH in percent.
- 採液態水的 Magnus 近似。空氣溫度限 0–40°C,RH 須大於 0% 且至多 100%。估計露點低於 −45°C 時超出本工具範圍。 Liquid-water Magnus approximation. Air must be 0–40°C with RH above 0% and at most 100%. Dew points below −45°C are outside this tool.
- 空氣及玻璃量測要取同一側。表面低於 0°C 時另查結霜。 Measure air and glass on the same side. Check frost separately below 0°C.
- 餘量 0–1°C 為此課的教學提醒帶,現場應按量測不確定性判斷。 The 0–1 K margin is a classroom flag. Compare against measurement uncertainty in practice.
計算結果 Results
單位一致性檢查 Unit Check
| 直徑 (mm) Diameter (mm) | 此摩擦率下的風量 (L/s) Airflow at This Friction Rate (L/s) | 查表結果 Table Result |
|---|
公式、單位與假設 Formulas, Units and Assumptions
A = πD² ÷ 4 A = πD² ÷ 4
v = V̇ ÷ A v = V̇ ÷ A
Δp/L = f × ρ × v² ÷ (2D) Δp/L = f × ρ × v² ÷ (2D)
風量先換成 m³/s,直徑換成 m,摩擦率用 Pa/m。查表值以 L/s 顯示,選徑以未取位數值為準。 Use m³/s, metres and Pa/m. The table displays L/s and picks a diameter using unrounded values.
- 原創教學表以 Darcy–Weisbach 式計算直圓管,空氣密度取 1.20 kg/m³,Darcy 摩擦因子固定為 0.020。 Darcy–Weisbach straight circular duct. Density 1.20 kg/m³ and Darcy factor 0.020.
- 選擇第一個能在目標摩擦率內送出所需風量的表列直徑。接頭、矩形管與噪音有各自的核對方法。 Choose the first suitable listed diameter. Check fittings, rectangular ducts and noise separately.