構造傳熱 Envelope Heat Transfer
U-factor 與多層熱阻 U-Factor and Layered Thermal Resistance
輸入各層厚度與導熱係數,從串聯熱阻反算整個構造的 U-factor。 Find the whole-assembly U-factor from layer thickness, conductivity and series resistance.
用示例練習公式,再核對自己的輸入、單位與假設。
構造傳熱 Envelope Heat Transfer
輸入各層厚度與導熱係數,從串聯熱阻反算整個構造的 U-factor。 Find the whole-assembly U-factor from layer thickness, conductivity and series resistance.
單一步驟負荷核對 Load Check
用總傳熱係數、淨面積和溫差核對構造傳熱。 Check conduction using the assembly U-factor, net area and temperature difference.
容量單位 Capacity Units
將同一冷卻容量轉成 BTU/h、W 或冷凍噸(ton)。 Convert the same cooling rate between BTU/h, watts and tons.
風量估算 Airflow Estimation
用同一筆峰值負荷,並列 0.045 CFM/(BTU/h) 與 400 CFM/ton 的結果。 Compare 0.045 CFM/(BTU/h) and 400 CFM/TR at the same peak load.
名義冷量核對 Nominal Capacity Check
將峰值負荷換成冷凍噸,試算增加 5%–15% 餘量後的目標容量。 Convert peak load to TR and add a teaching margin of 5%–15%.
濕度與表面溫度 Humidity and Surface Temperature
估算玻璃同一側空氣的露點,判斷表面是否接近冷凝。 Estimate same-side air dew point and compare with glass temperature.
風管尺寸入門 Duct Sizing Basics
由風量和每米摩擦壓降,查找教學直圓管管徑。 Find a teaching round duct diameter from airflow and target friction rate.
辨認計算域、邊界條件、網格與驗證問題。附 Python notebook 佔位。